壓力罐選型(波義耳定律)
壓力罐選型取決于所需的關(guān)鍵點(diǎn)是泵流量和壓力開關(guān)設(shè)置
建議減少1-2分鐘,以減少管道、泵端的短周期損失
頻繁啟動和停止,會縮短泵及控制器使用壽命
定壓供水選型:
Example: 流量50LPM
1.VF = 50LPM = 50 Litres draw off volume
(minimum 1 minute between pump starts)
2.PA = Atmospheric Pressure = 14.7Psi
3.P1 = Pre-Charge Tank Air Pressure = 68Psi
4.P2 = Cut-in Pressure = 70Psi
5.P3 = Cut-out Pressure = 90Psi
6.DF = Draw Down Coefficient
7.Tv = Pressure Tank Volume
Wet Tank Example(NB: wet tank P1=0)
DF= (14.7 / 84.7) - (14.7 / 104.7)
= (0.174) - (0.140)
= 0.034
TV= (50 / 0.034)
=1470 Litre tank volume
Diaphragm Tank Example
DF= (82.7 / 84.7) - (82.7 / 104.7)
= (0.976) - (0.790)
= 0.186
TV= (50 / 0.186)
=270 Litre tank volume